The BX-C/CB series Co2 Incubator simulates the environment in which cells/tissues are cultured in vitro, such as temperature, humidity, pH, etc. It can be widely used in cell culture, fermentation, hybridization, cell tissue research, and other fields such as cell biology, oncology, genetics, immunology, virus research cytology, and modern genetic engineering research.
Operating system: BRIGHT I intelligent operating system, 7-inch high-definition touch screen, user-friendly interface, can automatically compensate for control parameter values according to environmental changes
Data management system: Data management function: The controller can save more than 500000 data records (non SD card storage), view instrument recorded data and curves in real time, and support exporting with a USB flash drive in an unchangeable file format for viewing and backup, as well as tracing data
Event management system: The control system can automatically record device events with exact time, such as startup, shutdown, menu parameter settings and modifications, fault alarms, etc., making it convenient for customers to have a clear understanding of the device's operating status. It also supports exporting to a USB flash drive in an immutable file format for viewing and backup, and tracing data
Permission management system: a three-level permission management system, where each and every operator's operation will generate a unique traceable imprint in the event record
Heating system: Direct hot air sleeve design, three temperature zones with 8 units and 6 heating surfaces, fast heating rate, uniform temperature distribution, avoiding condensation of water vapor on the inner wall and glass door
Temperature protection: Independent adjustable temperature limit switch, which can effectively protect equipment and laboratory safety
Sterilization system: One click automatic 90 ℃ high temperature and high humidity sterilization, efficient and reliable sterilization process, all internal components are designed to withstand high temperatures, and do not need to be removed before sterilization
Internal forced airflow circulation ensures uniformity of temperature, humidity, and CO2 concentration
The bottom reservoir design allows for gentle airflow to sweep over the water surface during internal air circulation, carrying a large amount of water vapor into the air circulation, effectively accelerating the rise and recovery of humidity
After passing through the water surface, CO2 gas carries a large amount of water vapor into the cultivation space, which can wet the gas and balance the gas temperature, effectively avoiding condensation in the inner chamber
The interior is equipped with high-efficiency air filters to improve cleanliness, effectively prevent pollution, and enhance the measurement accuracy of CO2 sensors
The inner chamber is equipped with a pressure balance system to ensure the pressure inside and outside the incubator during daily use and high-temperature and high humidity sterilization, ensuring convenience and safety of use
The integrated mirror inner liner, with a large circular arc design, effectively avoids pollution and cleaning dead corners during the cultivation process, making it convenient for later use and maintenance
The perforated mirror reinforced stainless steel shelf adopts special bending treatment, greatly improving the overall strength and stability of the shelf. At the same time, it has an anti tipping design to ensure safe use
The box is equipped with universal adjustable casters, making it easy to move and fix the incubator. It also has the function of adjusting the levelness of the box, ensuring that cells are cultured in a horizontal flat state
The electrical components are located at the top of the box, with a large design space, which is convenient for later use, maintenance, regular maintenance, and overhaul
The glass door is equipped with a magnetic switch to monitor its status, which can reduce parameter fluctuations when opening the door
Adopting a single beam dual wavelength imported infrared IR sensor with high accuracy and zero drift
The glass door and the rear wall of the inner chamber are equipped with sampling and testing ports for direct measurement of parameters inside the chamber
There is a water level sensor at the bottom of the reservoir, which triggers a water shortage alarm to ensure safe cultivation
The reservoir is equipped with a quick plug drainage outlet, which facilitates users to regularly replace the water in the chassis and is easy to operate
Equipped with independent temperature protection device
USB interface, CO2 inlet, 485 interface
Door opening alarm: After the inner door is opened for a period of time, the equipment will automatically sound and light an alarm to remind users to restore the equipment's usage status in a timely manner
Dual temperature protection: control system over temperature protection+temperature limiting sensor dual temperature protection system, effectively preventing abnormal temperature rise from causing loss of cell samples
Low water level protection: There is a water level sensor at the bottom of the reservoir, which alarms for water shortage and ensures safe cultivation
Filter alarm: The internal circulating air filter comes with an alarm function. After a certain period of use, the device will remind the user to replace the filter in a timely manner to achieve continuous internal cleanliness
CO2 concentration abnormal alarm: If the equipment runs stably and encounters an abnormal increase or decrease in CO2 concentration, the equipment will automatically sound and light an alarm to remind the user
| Model | BX-100C/CB | BX-180C/CB | BX-260C/CB |
| Sterilization method | Moist heat sterilization/Uv sterilization | ||
| Temperature control range | RT+5~55 ℃ | ||
| Temperature uniformity | ± 0.5 ℃ | ||
| Temperature fluctuation | ± 0.3 ℃ | ||
| Temperature control accuracy | ± 0.1 ℃ | ||
| Relative humidity | >90% RH | ||
| CO2 intake pressure | 0.05~0.1MPa | ||
| CO2 measurement and control range | 0~20vol | ||
| CO2 control accuracy | ± 0.1% vol | ||
| CO2 recovery time | 6 minutes (at 5%) | ||
| CO2 intake time | 5 minutes (at 5%) | ||
| CO2 fluctuation | ± 0.1% | ||
| Dimensions(W × D × H) | 650×650×960mm | 750×740×1060mm | 800×780×1210mm |
| Internal cavity size(W × D × H) | 400×430×600mm | 500×520×700mm | 550×560×850mm |
| Workroom volume | 100L | 180L | 260L |
| Shelf(L × W ) | 350×375mm | 450×465mm | 500×505mm |
| Standard quantity of shelves | 3 | ||
| Maximum number of shelves | 14 | 18 | 22 |
| Load capacity of each shelf | 10kg | ||
| Environmental temperature range |
18~30 ℃ |
||
| Power supply | AC 220V (± 10%) 50/60Hz | ||
| Rated power | 900W | 950W | 1000W |
The Moist Heat Sterilization/UV Sterilization Co2 incubator simulates the environment in which cells/tissues are cultured in vitro, such as temperature, humidity, pH, etc. It can be widely used in cell culture, fermentation, hybridization, cell tissue research, and other fields such as cell biology, oncology, genetics, immunology, virus research cytology, and modern genetic engineering research.
Operating system: BRIGHT I intelligent operating system, 7-inch high-definition touch screen, user-friendly interface, can automatically compensate for control parameter values according to environmental changes
Data management system: Data management function: The controller can save more than 500000 data records (non SD card storage), view instrument recorded data and curves in real time, and support exporting with a USB flash drive in an unchangeable file format for viewing and backup, as well as tracing data
Event management system: The control system can automatically record device events with exact time, such as startup, shutdown, menu parameter settings and modifications, fault alarms, etc., making it convenient for customers to have a clear understanding of the device's operating status. It also supports exporting to a USB flash drive in an immutable file format for viewing and backup, and tracing data
Permission management system: a three-level permission management system, where each and every operator's operation will generate a unique traceable imprint in the event record
Heating system: Direct hot air sleeve design, three temperature zones with 8 units and 6 heating surfaces, fast heating rate, uniform temperature distribution, avoiding condensation of water vapor on the inner wall and glass door
Temperature protection: Independent adjustable temperature limit switch, which can effectively protect equipment and laboratory safety
Sterilization system: One click automatic 90 ℃ high temperature and high humidity sterilization, efficient and reliable sterilization process, all internal components are designed to withstand high temperatures, and do not need to be removed before sterilization
Internal forced airflow circulation ensures uniformity of temperature, humidity, and CO2 concentration
The bottom reservoir design allows for gentle airflow to sweep over the water surface during internal air circulation, carrying a large amount of water vapor into the air circulation, effectively accelerating the rise and recovery of humidity
After passing through the water surface, CO2 gas carries a large amount of water vapor into the cultivation space, which can wet the gas and balance the gas temperature, effectively avoiding condensation in the inner chamber
The interior is equipped with high-efficiency air filters to improve cleanliness, effectively prevent pollution, and enhance the measurement accuracy of CO2 sensors
The inner chamber is equipped with a pressure balance system to ensure the pressure inside and outside the incubator during daily use and high-temperature and high humidity sterilization, ensuring convenience and safety of use
The integrated mirror inner liner, with a large circular arc design, effectively avoids pollution and cleaning dead corners during the cultivation process, making it convenient for later use and maintenance
The perforated mirror reinforced stainless steel shelf adopts special bending treatment, greatly improving the overall strength and stability of the shelf. At the same time, it has an anti tipping design to ensure safe use
The box is equipped with universal adjustable casters, making it easy to move and fix the incubator. It also has the function of adjusting the levelness of the box, ensuring that cells are cultured in a horizontal flat state
The electrical components are located at the top of the box, with a large design space, which is convenient for later use, maintenance, regular maintenance, and overhaul
The glass door is equipped with a magnetic switch to monitor its status, which can reduce parameter fluctuations when opening the door
Adopting a single beam dual wavelength imported infrared IR sensor with high accuracy and zero drift
The glass door and the rear wall of the inner chamber are equipped with sampling and testing ports for direct measurement of parameters inside the chamber
There is a water level sensor at the bottom of the reservoir, which triggers a water shortage alarm to ensure safe cultivation
The reservoir is equipped with a quick plug drainage outlet, which facilitates users to regularly replace the water in the chassis and is easy to operate
Equipped with independent temperature protection device
USB interface, CO2 inlet, 485 interface
Door opening alarm: After the inner door is opened for a period of time, the equipment will automatically sound and light an alarm to remind users to restore the equipment's usage status in a timely manner
Dual temperature protection: control system over temperature protection+temperature limiting sensor dual temperature protection system, effectively preventing abnormal temperature rise from causing loss of cell samples
Low water level protection: There is a water level sensor at the bottom of the reservoir, which alarms for water shortage and ensures safe cultivation
Filter alarm: The internal circulating air filter comes with an alarm function. After a certain period of use, the device will remind the user to replace the filter in a timely manner to achieve continuous internal cleanliness
CO2 concentration abnormal alarm: If the equipment runs stably and encounters an abnormal increase or decrease in CO2 concentration, the equipment will automatically sound and light an alarm to remind the user
| Model | BX-100C/CB | BX-180C/CB | BX-260C/CB |
| Sterilization method | Moist heat sterilization/Uv sterilization | ||
| Temperature control range | RT+5~55 ℃ | ||
| Temperature uniformity | ± 0.5 ℃ | ||
| Temperature fluctuation | ± 0.3 ℃ | ||
| Temperature control accuracy | ± 0.1 ℃ | ||
| Relative humidity | >90% RH | ||
| CO2 intake pressure | 0.05~0.1MPa | ||
| CO2 measurement and control range | 0~20vol | ||
| CO2 control accuracy | ± 0.1% vol | ||
| CO2 recovery time | 6 minutes (at 5%) | ||
| CO2 intake time | 5 minutes (at 5%) | ||
| CO2 fluctuation | ± 0.1% | ||
| Dimensions(W × D × H) | 650×650×960mm | 750×740×1060mm | 800×780×1210mm |
| Internal cavity size(W × D × H) | 400×430×600mm | 500×520×700mm | 550×560×850mm |
| Workroom volume | 100L | 180L | 260L |
| Shelf(L × W ) | 350×375mm | 450×465mm | 500×505mm |
| Standard quantity of shelves | 3 | ||
| Maximum number of shelves | 14 | 18 | 22 |
| Load capacity of each shelf | 10kg | ||
| Environmental temperature range |
18~30 ℃ |
||
| Power supply | AC 220V (± 10%) 50/60Hz | ||
| Rated power | 900W | 950W | 1000W |
Factory ADD:No. 55 Zhengfeng Road, Caozili Town, Wuqing District, Tianjin City,China