The BXZ-I series General Drug Stability Test Chamber uses scientific and rigorous methods to simulate the long-term stable temperature, humidity, light, and ultraviolet environment required for drug failure assessment. This general drug stability laboratory is suitable for pharmaceutical companies to conduct factor testing, accelerated testing, and long-term testing on raw materials and finished drugs.
BRIGHT I control system can automatically compensate the value of control parameters according to the change of environment
Programmable multi-segment parameter setting: 30 segments 99 cycles design
The controller can store data records for more than 5 years (not stored by SD card), and record equipment events with exact time, and export them by U disk in unchangeable file format for viewing and backup, and trace the data
The administrator can assign 14 kinds of equipment operation permissions to 5 operators
Support data and curve online viewing
The circulating air volume can be adjusted manually according to the sample loading condition
Rapid recovery of temperature and humidity after opening the door
Protection function: upper and lower limit over temperature alarm, over temperature shutdown protection, door open alarm, water shortage alarm, sensor fault alarm, overload protection, leakage protection, compressor over temperature protection
Glass observation inner door design
Equipped with mechanical lock, prevents from opening at will
Equipped with printer
Imported illumination sensor, real-time monitoring and accumulation of the actual illumination received value
Illumination module shelf, illuminance is stepless adjustable, when the total illumination value is reached, the LED lamp will be turned off automatically
Illumination value is displayed in real-time and can be printed
Meet the test requirement of total illuminance not less than 1.2×106Lux·hr
|
Model |
BXZ-150I | BXZ-250I | BXZ-400I | BXZ-800I | BXZ-1000I |
| Volume [L] | 150 | 250 | 400 | 800 | 1000 |
|
Temp. Range without Humidification and without Illumination [°C] |
0~70 | ||||
|
Temp. Range without Humidification and with Illumination [°C] |
10~70 | ||||
|
Temp. Range with Humidification and without Illumination [°C] |
10~60 | ||||
|
Temp. Range with Humidification and with Illumination [°C] |
15~60 | ||||
| Temp. Resolution [°C] | 0.1 | ||||
| Temp. Fluctuation at 25°C [°C] | ±0.5 | ||||
| Temp. Uniformity at 25°C [°C] | ±1 | ±1.5 | ±2 | ||
| Humidity Range [%] | 30~95 | ||||
| Humidity Fluctuation [%] | ±3 | ±5 | |||
| Illuminance [Lux] | 0~10000 |
|
|
|
|
| Illuminance Deviation [Lux] | ±500 | ||||
| Power [W] | 2000 | 2050 | 2200 | 3850 | 3950 |
| Timer Range per Segment [h] | 1~9999 | ||||
| Internal Dimensions W×D×H [mm] | 510×390×760 | 510×450×1090 | 600×640×1050 | 1200×610×1100 | 1200×760×1100 |
| Housing Dimensions W×D×H [mm] | 650×820×1400 | 650×880×1724 | 745×1070×1695 | 1362×1068×1789 | 1362×1168×1789 |
| Number of Shelves (std./max.) [pc] | 3 / 4 | 4 / 7 | 8 / 16 | ||
Factory ADD:No. 55 Zhengfeng Road, Caozili Town, Wuqing District, Tianjin City,China
Tel/Wechat:8618522872961,8613012283680(Whatsapp)
E-mail:CHINAHJHT@outlook.com