Product Center

BXM-FE series vertical pressure steam sterilizer
  • Product Category: Products Autoclave / Sterilizer
  • product description:The BXM-FE series vertical pressure steam sterilizer can be used for high-pressure steam sterilization of conventional sterilization materials such as culture media, instruments, glassware, and containers; Sterilization of relatively sealed containers (penicillin bottles, blue cap bottles, etc.), large volume dense sterilization materials such as instrument packs, large bottle culture media, and dense fabric packs, positive pressure pulse exhaust function ensures thorough discharge of cold air, improves steam penetration, and ensures sterilization effectiveness.
  • Products Description


    The BXM-FE series vertical pressure steam sterilizer can be used for high-pressure steam sterilization of conventional sterilization materials such as culture media, instruments, glassware, and containers; Sterilization of relatively sealed containers (penicillin bottles, blue cap bottles, etc.), large volume dense sterilization materials such as instrument packs, large bottle culture media, and dense fabric packs, positive pressure pulse exhaust function ensures thorough discharge of cold air, improves steam penetration, and ensures sterilization effectiveness.


    Products Features


    1

    Intelligent control system: BRIGHT II operating system can automatically compensate the value of control parameters according to the change of environment

    2

    Hd large screen display: 7 inch HD touch screen, sterilization temperature, sterilization time, sterilization procedures, working status diagram, alarm information, Gregorian calendar time and other key parameters displayed on the same screen


    3

    Ergonomic large screen: HD large screen can be freely flipped open to adjust the display Angle, to ensure the best display Angle of the large screen, while preventing light reflection from external light sources


    4

    Foot door structure: foot clamshell door structure, with mechanical self-locking and electronic interlocking double protection

    5

    Anti-scalding design of the whole machine: the upper cover is equipped with integrated polymer material, which can effectively reduce the surface temperature in the sterilization process and prevent scalding operators

    6

    Rapid cooling system: after sterilization can accelerate the cooling rate, shorten the opening time

    7

    Pipeline partition distribution: Electrical circuit and pipeline circuit are arranged on both sides of the sterilizer, which is more reasonable in structure and safer in use

    8

    Mirror inner liner: The inner liner through the multi-eye polishing process, to achieve the mirror reflection effect, not only to ensure the overall internal cleanliness, but also convenient for use and maintenance

    9

    Inner cylinder with large curvature: different from the traditional inner cylinder and flange structure, we adopt the large curvature flange technology, which makes the transition smooth at the upper mouth and effectively prevents the operator from scratching his hand when taking the basket

    10

    Preset a variety of programs: built-in 26 sterilization programs +4 melting insulation programs, while the operator can modify and save the program, the next sterilization can be directly called

    11

    Sample time mode: The sterilization procedure can be set when the sample temperature reaches the set temperature, to help operators master the actual sterilization time of the sample

    12

    Data management system: The control system can record equipment alarm records, historical data and operation logs by itself, and with the exact time, convenient for customers to clearly grasp the operating state of the equipment, and support the U disk in unchangeable file format export for viewing and backup, and to trace the data

    13

    Multi-level rights management: The administrator can assign all the device operation rights (a total of 12 operation rights) to 20 operators. The operations performed by each operator are uniquely traced in the operation logs

    14

    8 point temperature calibration: Sterilization temperature, sample temperature support 8 point temperature calibration, temperature measurement deviation can be manually corrected

    15

    Boiling point setting function: in high altitude areas, boiling point can be set according to local conditions to ensure that sterilization temperature can be achieved

    16

    Opening temperature setting: The operator can modify the opening temperature according to the use of conditions, to ensure the safety of use

    17

    One-button exhaust drainage: Support one-button exhaust drainage to complete sterilization, convenient for operators to maintain the sterilizer

    18

    Calendar reservation operation: with the Gregorian calendar reservation operation function, convenient operators strictly control the running time

    19

    Six-level exhaust steam setting: support six-level exhaust steam setting, according to the sterilization sample set after sterilization steam mode

    20

    Historical curve view: support to view the cavity temperature, sample temperature historical curve

    21

    Positive pressure pulse exhaust: 6 levels of cold air discharge procedures can be set to ensure that cold air discharge thoroughly

    22

    Low water level double protection: water level detection probe + anti-dry burning probe double low water level protection, too low water level can not start the sterilization procedure

    23

    Other safety protection: fault detection function, lock tongue limit protection, collecting cylinder is not in place alarm, over temperature protection, over pressure self-leakage protection, anti-scalding protection, overload protection, short circuit protection, leakage protection, independent electronic overpressure and other multiple safety protection

    24

    The standard sample temperature probe can realize real-time check of sample temperature

    25

    One 485 data port, one USB port and one G1/2A verification port are standard

    26

    Optional biosafety filter, verification lead, embedded printer 




    Products Technical Parameters


    Model BXM-65FE BXM-90FE
    Volume [L] 65 90
    Drum diameter[mm] 400 400
    Power Supply [V, Hz] 220±10%, 50±2% 220±10%, 50±2%
    Environment Temp. [°C] 5~40 5~40
    Environment Humidity [%RH] 20~80 20~80
    Power [kW] 3.2 3.6
    Sterilization Temp. [°C] 105~135 105~135
    Temp. fluctuations [°C] ˂±1 ˂±1
    Temp. Uniformity[°C] ≦±1 ≦±1
    Melting Temp. [°C] 60~100 60~100
    Heat Preservation Temp. [°C] 40-60 40-60
    Sterilization Timer Range [min] 0-240 0-240
    Melting Timer Range [min] 0-6000 0-6000
    Heat Preservation Timer Range [min] 0-6000 0-6000
    Reservation Range [min] 0-6000 0-6000
    Design Pressure [MPa] 0.39 0.39
    Working Pressure [MPa] 0.24 0.24
    Housing Dimensions W×D×H [mm] 605*513*915 605*513*1040
    Cavity size (mm) Ø380*610 Ø380*735
    Basket Dimensions [mm] 360*225 360*200
    Number of Baskets [pc] 2

    3

  Factory ADD:No. 55 Zhengfeng Road, Caozili Town, Wuqing District, Tianjin City,China 

 Tel/Wechat:8618522872961,8613012283680(Whatsapp) 

 E-mail:CHINAHJHT@outlook.com

Copyright © 2026 Tianjin HJHT Instrument Co.,Ltd