The BXS-I series Extensible Test Chamber simulates the long-term stable temperature, humidity, light, and UV environment required for drug failure evaluation in a scientific and rigorous manner. It is suitable for pharmaceutical companies to conduct factor tests, accelerated tests, and long-term tests on raw materials and finished drugs.
BRIGHT I control system can automatically compensate the value of control parameters according to the change of environment
Programmable multi-segment parameter setting: 30 segments 99 cycles design
The controller can store data records for more than 5 years (not stored by SD card), and record equipment events with exact time, and export them by U disk in unchangeable file format for viewing and backup, and trace the data
The administrator can assign 14 kinds of equipment operation permissions to 5 operators
Support data and curve online viewing
The circulating air volume can be adjusted manually according to the sample loading condition
Rapid recovery of temperature and humidity after opening the door
Protection function: upper and lower limit over temperature alarm, over temperature shutdown protection, door open alarm, sensor fault alarm, overload protection, leakage protection, compressor over temperature protection
Glass observation inner door design
Equipped with mechanical lock, prevents from opening at will
Equipped with printer
| Model | BXS-150I | BXS-250I | BXS-400I |
| Volume [L] | 150 | 250 | 400 |
| Temp. Range [°C] | 0~70 | ||
| Temp. Resolution [°C] | 0.1 | ||
| Temp. Fluctuation at 25°C [°C] | ±0.5 | ||
| Temp. Uniformity at 25°C [°C] | ±1 | ±1.5 | |
| Power [W] | 1300 | 1350 | 1400 |
| Timer Range per Segment [h] | 1~9999 | ||
|
Internal Dimensions W×D×H [mm] |
510×390×760 | 510×450×1090 | 600×640×1050 |
|
Housing Dimensions W×D×H [mm] |
650×820×1400 | 650×880×1724 | 745×1070×1695 |
|
Number of Shelves (std./max.) [pc] |
3 / 4 | 4 / 7 | |
|
Door Type / Number of Shelves per Layer [pc] |
One Side / 1 | ||
| Humidity Control Extended | |||
|
Temp. Range without Humidification [°C] |
0~70 | ||
|
Temp. Range with Humidification [°C] |
10~60 | ||
| Humidity Range [%] | 25~95 | ||
| Humidity Fluctuation [%] | ±3 | ||
| Power [W] | 1900 | 1950 | 2000 |
| Illumination (UV) Control Extended | |||
|
Temp. Range without Illumination [°C] |
0~70 | ||
|
Temp. Range with Illumination [°C] |
10~70 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power / Number of Illumination Shelf [W/pc] |
1400 / 1 | 1450 / 1 | 1600 / 1 |
|
Number of Illumination Module Shelf [pc] |
1 | ||
|
Max. Number of Illumination Source Shelf [pc] |
1 | 2 | |
|
Humidity And Illumination (UV) Control Extended |
|||
|
Temp. Range without Humidification and without Illumination [°C] |
0~70 | ||
|
Temp. Range without Humidification and with Illumination [°C] |
10~70 | ||
|
Temp. Range with Humidification and without Illumination [°C] |
10~60 | ||
|
Temp. Range with Humidification and with Illumination [°C] |
15~60 | ||
| Humidity Range [%] | 30~95 | ||
| Humidity Fluctuation [%] | ±3 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power / Number of Illumination Shelf [W/pc] |
2000 / 1 | 2050 / 1 | 2200 / 1 |
|
Number of Illumination Module Shelf [pc] |
1 | ||
|
Max. Number of Illumination Source Shelf [pc] |
1 | 2 | |
| Model | BXS-800I | BXS-1000I | BXS-1600I |
| Volume [L] | 800 | 1000 | 1600 |
| Temp. Range [°C] | 0~70 | ||
| Temp. Resolution [°C] | 0.1 | ||
| Temp. Fluctuation at 25°C [°C] | ±0.5 | ||
| Temp. Uniformity at 25°C [°C] | ±1.5 | ±2 |
|
| Power [W] | 2900 | 3000 | 3100 |
| Timer Range per Segment [h] | 1~9999 | ||
|
Internal Dimensions W×D×H [mm] |
1200×610×1100 | 1200×760×1100 | 1400×850×1350 |
|
Housing Dimensions W×D×H [mm] |
1362×1068×1789 | 1362×1168×1789 | 1562×1238×2039 |
|
Number of Shelves (std./max.) [pc] |
8 / 16 | ||
|
Door Type / Number of Shelves per Layer [pc] |
Side-by-side / 2 | ||
| Humidity Control Extended | |||
|
Temp. Range without Humidification [°C] |
0~70 | ||
|
Temp. Range with Humidification [°C] |
10~60 | ||
| Humidity Range [%] | 30~95 | ||
| Humidity Fluctuation [%] | ±5 | ||
| Power [W] | 3500 | 3600 | 3700 |
| Illumination (UV) Control Extended | |||
|
Temp. Range without Illumination [°C] |
0~70 | ||
|
Temp. Range with Illumination [°C] |
10~70 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power / Number of Illumination Shelf [W/pc] |
3250 / 2 | 3350 / 2 | 3450 / 2 |
|
Number of Illumination Module Shelf [pc] |
1 | ||
|
Max. Number of Illumination Source Shelf [pc] |
5 | 7 | |
|
Humidity And Illumination (UV) Control Extended |
|||
|
Temp. Range without Humidification and without Illumination [°C] |
0~70 | ||
|
Temp. Range without Humidification and with Illumination [°C] |
10~70 | ||
|
Temp. Range with Humidification and without Illumination [°C] |
10~60 | ||
|
Temp. Range with Humidification and with Illumination [°C] |
15~60 | ||
| Humidity Range [%] | 30~95 | ||
| Humidity Fluctuation [%] | ±5 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power / Number of Illumination Shelf [W/pc] |
3850 / 2 | 3950 / 2 | 4050 / 2 |
|
Number of Illumination Module Shelf [pc] |
1 | ||
|
Max. Number of Illumination Source Shelf [pc] |
5 | 7 | |