The BXS-SI series Extensible Test Chamber simulates the long-term stable temperature, humidity, light, and UV environment required for drug failure evaluation in a scientific and rigorous manner. It is suitable for pharmaceutical companies to conduct factor tests, accelerated tests, and long-term tests on raw materials and finished drugs.
7-inch high-definition touch screen with touch operation, making the display more intuitive and easy to operate
The BRIGHT II intelligent operating system can automatically compensate for control parameter values according to environmental changes
Programmed multi segment parameter settings: 30 segment 99 cycle design
Equipped with data management function: The controller can store data records for more than 10 years (non SD card storage), and can view instrument temperature record data or curves in real-time. It also supports exporting in an unchangeable file format using a USB flash drive for viewing and backup, and tracing the data
Equipped with event management function: The control system can automatically record device events with exact time, such as startup, shutdown, door opening, door closing, menu parameter setting and modification, fault alarm, etc., making it easy for customers to clearly grasp the device operation status. It also supports exporting in an unchangeable file format using a USB flash drive for viewing and backup, and tracing data
Permission level management function: Administrators can customize and assign all operating permissions of the device (with 14 different operating functions) to 5 operators, and each operator's operation will generate a unique traceable imprint in the event record
The equipment comes with a circulating air volume adjustment system, which can manually adjust the circulating air volume according to the sample loading situation to ensure that the equipment reaches a good operating state
Equipped with multi-level password management function to prevent arbitrary operation
The variable frequency refrigeration system ensures fast temperature recovery after opening the door and ensures long-term frost free and stable operation of the equipment under non extreme conditions
Equipped with an inner door anti fog system to avoid affecting sample observation when opening the outer door, and greatly reduce the risk of condensation and condensation on the inner door
Improve protection functions: upper and lower limit overtemperature alarm, overtemperature shutdown protection, door opening alarm, sensor fault alarm, overload protection, leakage protection, compressor overtemperature protection
Double door design with panoramic tempered glass observation inner door to avoid parameter fluctuations during sample observation
Equipped with a detachable compressor condenser maintenance window for customers to regularly clean the condenser
Equipped with an internal door condensate recovery system and a cavity condensate recovery system
The inner cavity adopts a rounded design for easy cleaning
The shelf adopts a drawer type structure design, with arbitrary positioning for convenient sample loading and sampling
There is a verification hole with an inner diameter of 3cm on the left and right sides of the device, which is convenient for customers to wire during the measurement or verification process
The door seal adopts an advanced magnetic seal structure, which has good sealing effect and saves labor when opening and closing doors compared to mechanical buckle sealing structure
| Model | BXS-150SI | BXS-250SI | BXS-400SI |
| Volume [L] | 150 | 250 | 400 |
| Temp. Range [°C] | -10~85 | ||
| Temp. Resolution [°C] | 0.1 | ||
| Temp. Fluctuation at 25°C [°C] | ±0.5 | ||
| Temp. Uniformity at 25°C [°C] | ±1 | ±1.5 | |
| Power [W] | 1300 | 1350 | 1400 |
| Timer Range per Segment [h] | 1~9999 | ||
|
Internal Dimensions W×D×H [mm] |
506×400×750 | 506×450×1100 | 600×610×1100 |
|
Housing Dimensions W×D×H [mm] |
669×772×1444 | 669×822×1794 | 763×982×1794 |
|
Number of Shelves (std./max.) [pc] |
3 / 6 | 4 / 12 | |
|
Door Type / Number of Shelves per Layer [pc] |
One Side / 1 | ||
| Humidity Control Extended | |||
|
Temp. Range without Humidification [°C] |
-10~85 | ||
|
Temp. Range with Humidification [°C] |
10~60 | ||
| Humidity Range [%] | 15~98 | ||
| Humidity Fluctuation [%] | ±3 | ||
| Power [W] | 1900 | 1950 | 2000 |
| Illumination (UV) Control Extended | |||
|
Temp. Range without Illumination [°C] |
-10~85 | ||
|
Temp. Range with Illumination [°C] |
0~85 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power [W] |
1400 | 1450 | 1600 |
|
Max. Number of Illumination Shelf [pc] |
2 | 4 | |
|
Humidity And Illumination (UV) Control Extended |
|||
|
Temp. Range without Humidification and without Illumination [°C] |
-10~85 | ||
|
Temp. Range without Humidification and with Illumination [°C] |
0~85 | ||
|
Temp. Range with Humidification and without Illumination [°C] |
10~60 | ||
|
Temp. Range with Humidification and with Illumination [°C] |
15~60 | ||
| Humidity Range [%] | 15~98 | ||
| Humidity Fluctuation [%] | ±3 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power[W] |
2000 | 2050 | 2200 |
|
Max. Number of Illumination Shelf [pc] |
2 |
4 |
|
| Model | BXS-800SI | BXS-1000SI | BXS-1600SI |
| Volume [L] | 800 | 1000 | 1600 |
| Temp. Range [°C] | 0~85 | ||
| Temp. Resolution [°C] | 0.1 | ||
| Temp. Fluctuation at 25°C [°C] | ±0.5 | ||
| Temp. Uniformity at 25°C [°C] | ±1.5 | ±2 | |
| Power [W] | 2500 | 2600 | 2700 |
| Timer Range per Segment [h] | 1~9999 | ||
|
Internal Dimensions W×D×H [mm] |
1200×610×1100 | 1200×760×1100 | 1400×850×1350 |
|
Housing Dimensions W×D×H [mm] |
1362×980×1782 | 1362×1130×1782 | 1562×1220×2040 |
|
Number of Shelves (std./max.) [pc] |
4 / 12 | ||
|
Door Type / Number of Shelves per Layer [pc] |
Side-by-side / 1 | ||
| Humidity Control Extended | |||
|
Temp. Range without Humidification [°C] |
0~85 | ||
|
Temp. Range with Humidification [°C] |
10~60 | ||
| Humidity Range [%] | 20~98 | ||
| Humidity Fluctuation [%] | ±5 | ||
| Power [W] | 3100 | 3200 | 3300 |
| Illumination (UV) Control Extended | |||
|
Temp. Range without Illumination [°C] |
0~85 | ||
|
Temp. Range with Illumination [°C] |
10~85 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power [W] |
2850 | 2950 | 3050 |
|
Max. Number of Illumination Shelf [pc] |
4 | ||
|
Humidity And Illumination (UV) Control Extended |
|||
|
Temp. Range without Humidification and without Illumination [°C] |
0~85 | ||
|
Temp. Range without Humidification and with Illumination [°C] |
10~85 | ||
|
Temp. Range with Humidification and without Illumination [°C] |
10~60 | ||
|
Temp. Range with Humidification and with Illumination [°C] |
15~60 | ||
| Humidity Range [%] | 20~98 | ||
| Humidity Fluctuation [%] | ±5 | ||
| Illuminance [Lux] | 0~10000 | ||
| Illuminance Deviation [Lux] | ±500 | ||
| UV Amplitude [W/m2] * | 0~2 | ||
| UV Spectral Range [nm] * | 320~400 | ||
|
Power [W] |
3450 | 3550 | 3650 |
|
Max. Number of Illumination Shelf [pc] |
4 |
||
Factory ADD:No. 55 Zhengfeng Road, Caozili Town, Wuqing District, Tianjin City,China
Tel/Wechat:8618522872961,8613012283680(Whatsapp)
E-mail:CHINAHJHT@outlook.com
Copyright © 2026 Tianjin HJHT Instrument Co.,Ltd